This system features high-efficiency hot and cold vacuum extraction with a vacuum level of -0.95 to -1.0 bar, supported by a dual-pump, 8-channel vacuum pipeline design for uniform performance. Its large SUS304 stainless steel inner tank (2900×4300×2700mm) is heated across three independent zones with a total power of 120kW, allowing precise temperature control from room temperature up to 150°C, with a working temperature around 120°C and a rapid heating rate of 5–10°C per minute. A 0.75kW exhaust fan enables fast cooling after processing, while quick-connect vacuum lines and a manual double-opening door ensure both operational efficiency and ease of maintenance.

For more customized cases, please click here to see details. Or you could contact us (eshop.lab1st.com) for more information.

Features:

  • The vacuum degree during hot extraction of glass is -0.95bar to -1.0bar, which can be hot or cold
  • Inner tank size: width 2900*depth 4300*height 2700mm
  • Controlled in three temperature zones, total power 120Kw
  • Temperature range: adjustable from room temperature to +150℃ (working temperature is about 120℃)
  • Heating rate is about 5℃-10℃/min (RT~120℃)
  • Inner tank material: SUS304, made of 1.28MM steel plate
  • Manual double-opening door
  • Equipped with 0.75KW exhaust fan, which can be used for cooling products after heating
  • Two vacuum pipelines outside the box, adopting a double-tube double-pump design, each vacuum pump is connected to 1, the main pipeline enters the box and is divided into 4 pipelines, 2 The main pipelines enter the box and are divided into 4 channels for vacuum extraction on the left and right, a total of 8 channels, and the vacuum degree of the 2 main pipelines can be monitored. The stainless steel KF40 wave wire tube is quickly connected to the male and female heads of the frame vacuum chamber.

Customized Contents:

Model LBE-V2
Basic Information
Function Used for glass initial pressure vacuuming
Vacuum Range Vacuum during glass thermal extraction is from -0.95bar to -1.0bar
Vacuum Method Can be heated or cooled vacuum extraction
Equipment Base Ground-mounted, requiring foundation treatment to be level with the equipment for easy handling of glass carts
Oven Loading/Unloading Manual loading and unloading of material rack
Ground Load Capacity Ground should support approximately 4000kg, including forklift, glass products, and rack weight
Power 120KW
Dimension
Internal Dimension [W×D×H] 2900 × 4300 × 2700mm
External Dimension [W×D×H] 4540 × 3490 × 3090mm
Temperature Control
Control Mode Controlled by three temperature zones
Temperature Range Adjustable from room temperature to +150°C (working temperature approximately 120°C)
Heating Rate About 5°C-10°C /min (RT°C~120°C)
Material
Shell Material Made of 1.2-1.5 mm thick cold-rolled or composite steel plates
Surface coated with high-temperature electrostatic powder, color R9001 (off-white)
Surface polished and ground, ensuring no scratches, dents, or visible imperfections
Chamber Material Constructed with 1.28 mm thick SUS304 stainless steel
Full welding at insulation joints to ensure airtightness for vacuum applications
Reinforced with 50×50×2 mm angle steel framework, maintaining strength across all surfaces and accommodating thermal expansion and contraction to prevent deformation
Double Doors Manual double-door access at both the front and rear
Each door fitted with an observation window
Heavy-duty chrome-plated triangular hinges on both sides
Each door secured with a chrome-plated square steel lock)
Exhaust System Intake and exhaust ports located on the top, each 90 mm in diameter
Equipped with a 0.75 kW exhaust fan for rapid cooling after heating
Cart Access Floor-mounted design; requires foundation leveling with equipment base for smooth cart movement
Supports easy loading and unloading of glass carts (provided by the user)
Vacuum Ports Side-mounted vacuum connections using KF40 fittings for external vacuum pump linkage
Vacuum level for glass processes maintained between -0.95 and -1.0 bar
Two independent vacuum pipelines, each powered by a separate pump; each main line branches into four internal pipelines
A total of eight vacuum points inside the chamber, with real-time vacuum monitoring on both main lines
Stainless steel KF40 flexible bellows with quick-connect couplings ensure reliable vacuum sealing

All the Standard Shipping package will be delivery by standard logistics, such as DHL, FedEX, UPS, etc (shipping terms: DAP). We also provide Sea Shipping, please contact us (eshop@lab1st.com) or chat with us online for real-time shipping cost. Please note that we are day off on the weekends and holidays.

If the merchandise is in stock, we will ship it within 3 to 7 business days for Standard Shipping and about 20 to 30 business days for Sea Shipping. If it is out of stock, we will inform you the estimated delivery time according to different products. All orders will be processed within 2 days (handing time).

Environmental Certificate

Our products are not just built better, they are built responsibly.

Fast & Safe Shipping

We will ship every Package speedily with care.

1-Year Warranty

Our product warranties ensure quality you can trust.

Returns & Exchanges

Our one-staff customer service teams is standing by to help.

Certificates

Frequently Asked Questions

Yes, all of our products have CE marked.

All the Standard Shipping package will be delivery by standard logistics, such as DHL, FedEX, UPS, etc (shipping terms: DAP). We also provide Sea Shipping, please contact us (eshop@lab1st.com) or chat with us online for real-time shipping cost. Please note that we are day off on the weekends and holidays.

If the merchandise is in stock, we will ship it within 3 to 7 business days for Standard Shipping package(s) and about 20 to 30 business for Sea Shipping package(s). If it is out of stock, we will inform you the estimated delivery time according to different products.

To cancel an order, please submit a Support Form with “Cancel/Change Order” as reason for inquiry. Please include your order number in the body or subject line of the email to help us resolve the issue right away. Since orders often ship in 3--7 days after they are placed, it is important to contact us as soon as possible so that we can stop the order before it ships. Once the order is picked up we cannot cancel the order, but we can initiate a return. Please be aware that if the product is customized and there are no quality problems, it cannot be canceled, returned, or exchanged once the customization is completed.

Usually, our lab equipment can not customize and our most of our processing equipment can, if you're not sure, please contact us.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)